• Gossen Metrawatt
  • Camille Bauer

Characteristic Values

SECULIFE DP PRO SECULIFE IF+ SECULIFE DF BASE SECULIFE DF PRO SECULIFE ES PRO SECULIFE ES XTRA SECULIFE DP BASE SECULIFE ES PRIME
Item number M6950 M695D M695Q M695R M695B M695C M695S M695U
Product details page Details Details Details Details Details Details Details Details
Dimensions, length / mm 220mm 220mm 370mm 220mm
Dimensions, width / mm 140mm 140mm 370mm 140mm
Dimensions, height / mm 80mm 80mm 290mm 80mm
Weight 0.9kg 0.45kg 2.3kg 2.3kg 1.6kg 2.3kg 0.521kg 2.3kg
Operating temperature 15°C - 30°C 0°C - 50°C 15°C - 40°C 15°C - 40°C 15°C - 30°C 15°C - 40°C 0°C - 50°C 15°C - 40°C
Storage temperature -40°C - 60°C -40°C - 60°C -20°C - 65°C -20°C - 65°C -40°C - 60°C -20°C - 65°C -40°C - 60°C -20°C - 65°C
USB interface x
Display Two graphic LC displays, 128 x 64 pixels, white background illumination (LED) Graphic LCD display, 128 x 64 pixels Graphic LCD display / 256 x 64 pixels Graphic LCD display, 128 x 64 pixels 5 digits, 7-segment LCD
Background illumination of LC display x x
Backlight
Continuity test connections
RS232 x
Memory setting EEPROM, all parameters EEPROM, all parameters
Battery life (continuous operation - off) 0h - 80h 80h - 8760h
ECG NSR
ST segment elevation
ECG performance
Respiration function
NIBP function
Pressure gauge x
Pacemaker
Connections for pressure measurement Male Luer connector Male Luer connector
fetal/maternal
Training mode
Digital filters pressure measurement 1 to 255 averaged measured values
Integrated configuration function x
Temperature measurement RTD x
Illuminance measurement function
Memory function MEM
Entry of correction value CORR
Indication of Lux/Foot candle
Automatic shutdown 0 to 30 min.
Autorange function
Control element 6 keys
Hold function and max function for display x
Manual range function x
Range hold function x
Screen size 14.5 cm QVGA 18-bit color touchscreen 14.5 cm QVGA 18-bit color touchscreen
Housing 8.6 x 24.9 x 27.2 cm / ABS plastic 8.6 x 23.1 x 20.3 cm / ABS plastic 19.8 x 31.8 x 57.2 cm / aluminum 195.3 x 100.8 x 46.2 mm, ABS plastic 19.8 x 31.8 x 57.2 cm / aluminum
Chamber housings
Weight of chambers
Power supply 2 ea. 9 V battery 2 ea. 9 V battery ON < 150 mA, OFF < 40 uA Battery: 9 V alkaline
Power supply of chambers
External power supply unit 10 V, 300 mA , BE 2006 PE[220 V AC] US EU Without SECULIFE OX 9 V DC, 200 mA, with SECULIFE OX 10 V DC, 500 mA 9 V, 50 mA DC
Flow range 3.5 ml chamber
Flow range 35 ml chamber
Flow resolution
Flow accuracy
Time resolution internal
Measurement method Biphasic
Load resistance 50Ohm
Screen resolution 0.1J
Measurement time slot 100ms
Absolute maximum peak voltage 6000V
Pulse width 100ms
Voltage lower range
Voltage upper range
Max. current 24Ah - 120Ah
Max. energy 50J - 1000J
Accuracy lower range +/- 2% rdg. for > 20 Joule
Threshold 20V - 100V
Amplitude rendition lower range 1 mV / 1000 V arrestor I
Amplitude rendition upper range 1 mV / 1000 V arrestor I
Test pulse lower range 5 Joule +/- 20%
Test pulse upper range
Front plate Lexan / back-printed Lexan / back-printed Lexan / back-printed Lexan / back-printed
Accuracy upper range
Voltage supply adapter
RF current transformer (50 ?)
RF current transformer attenuation
Voltage (RMS) input resolution
Voltage resolution 0.1 mV
Measuring range for frequency
Accuracy of input voltage range
Input, resistor
Current (with 0.1:1 CT) resolution
Current (with 1:1 CT) resolution
Power resolution
Crest factor resolution 0.1 0.1
Maximum input voltage
Input connections 1 Ethernet
1 PS/2keyboard
1 serial
3 USB
Mouse
4 mm I/O safety sockets
Output connections 1 BNC oscilloscope
25-pin Hypertronics footswitch connection
A/D resolution 14
A/D speed 64
Bandwidth 50kHz - 10000kHz
Accuracy of measurement 1% rdg.
Current range lower range 2mA - 700mA
Current range upper range 20mA - 7000mA
Current resolution (lower - upper range) RMS 0.1mA - 1mA
Power range (watts) 500W
Current resolution (watts) 0.1W
Crest factor range 1.4 - 500
Input voltage range 0.20 to 70.0 mV RMS (lower range)
20 to 700.0 mV RMS (upper range)
mV peak / peak-peak range 0 - 1
Internal relays for settings and selection of loads 10
Range of internal loads 0Ohm - 6400Ohm
Accuracy of internal loads 1% non-inductive
Line values ??of internal loads 1 Ohm : 25 W
2 Ohm : 50 W
4 Ohm : 100 W
Remaining loads: 225 W
Load bank operating cycle 10 seconds on, 30 seconds off
Power demand (ON - OFF)
Pressure measuring range
Resolution pressure measurement
Maximum gauge pressure
Pressure accuracy
Load cooling