• Gossen Metrawatt
  • Camille Bauer

Characteristic Values

METRALINE DM 41 METRAHIT WORLD METRAmax 12 METRAHIT 2+ METRALINE DM 62 METRALINE DM 61
Item number M192A M206A M212A M205A M197A M194A
Product details page Details Details Details Details Details Details
Display
Indication Digital Digital Analogue/digital Analogue/digital Digital Analogue/digital
Indication digits 4000 6000 4000 6000 6600 6600
Analogue bar graph display x x x x x
Analogue bar graph display analogue/logarithmical
Multiple display x x
Measuring range selection Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic
Basic data
Type of measurement Averaging TRMS Averaging TRMS TRMS Averaging
True RMS measurement x x x
Basic accuracy 0.5% 0.5% 0.5% 0.5% 0.4% 0.4%
Measuring circuit category CAT III CAT IV CAT III CAT III CAT IV CAT III
Max. voltage measuring circuit category 600V 600V 300V 600V 600V 600V
Relative value measurement x x x x x x
Min. value storage x x x x x x
Maximum value storage x x x x x x
Peak value memory x x x
Special functions
Explosion-tested version
Power and energy measurement
Harmonics analysis/power quality
Crest factor measurement
Rotational speed measuring x
Duty cycle measurements x x x
Pulse freqency measurement MHz @ 5V TTL
Inductance measurement
Interturn short-circuit high-voltage test
Automatic circuit breaker
Voltage measurement
Voltage measurement types DC
AC
DC
AC
DC
AC
DC
AC
DC
AC
DC
AC
With decibel measurement (dB)
Voltage measuring range DC 0.0001V - 600V 0.0001V - 1000V 0.0001V - 600V 0.0001V - 600V 0.0001V - 1000V 0.0001V - 1000V
Voltage measuring ranges DC 600 V
400 mV
4 V
40 V
400 V
600 mV
6 V
60 V
600 V
1000 V
400 mV
4 V
40 V
400 V
600 V
600 mV
6 V
60 V
600 V
600 mV
6 V
60 V
600 V
1000 V
600 mV
6 V
60 V
600 V
1000 V
Max. voltage measuring range, DC 600V 1000V 600V 600V 1000V 1000V
Lowest resolution, DC voltage 0.1 mV 0.1 mV 0.1 mV Other 0.1 mV 0.1 mV
Internal resistance volt DC 11
20
10
10
5,2
5
0,4
10
11
20
10
5,2
5
11
10
100
11
10
100
Voltage measuring range AC 0.0001V - 600V 0.0001V - 1000V 0.0001V - 600V 0.0001V - 600V 0.0001V - 1000V 0.0001V - 1000V
Voltage measuring ranges AC 600 V
400 mV
4 V
40 V
400 V
600 mV
6 V
60 V
600 V
1000 V
400 mV
4 V
40 V
400 V
600 V
600 mV
6 V
60 V
600 V
600 mV
6 V
60 V
600 V
1000 V
600 mV
6 V
60 V
600 V
1000 V
Max. voltage measuring range, AC 1000V 1000V 600V 600V 1000V 1000V
Lowest resolution, AC voltage 0.1 mV 0.1 mV 0.1 mV 0.1 mV 0.1 mV 0.1 mV
Frequency range volt AC 20Hz - 1000Hz 30Hz - 800Hz 20Hz - 500Hz 30Hz - 800Hz 20Hz - 2000Hz 20Hz - 2000Hz
Internal resistance volt AC 10
11
8,1
4,6
4,4
0,4
10
11
20
8,1
4,6
4,4
10
11
100
10
11
100
Current measurement
Current measurement types DC
AC
DC
AC
DC
AC
DC
AC
DC
AC
DC
AC
Current measurement range DC 0,00001A - 10A 0,00001A - 10A 0,00001A - 10A 0,00001A - 10A 0,00001A - 10A 0,00001A - 10A
Current measuring ranges DC 10:00 AM
40 mA
400 mA
60 mA
600 mA
6:00 AM
10:00 AM
40 mA
400 mA
10:00 AM
60 mA
600 mA
6:00 AM
10:00 AM
60 mA
600 mA
10:00 AM
60 mA
600 mA
10:00 AM
Max. current measuring range, DC 10A 10A 10A 10A 10A 10A
Lowest resolution, DC current 10 µA 10 µA 10 µA 10 µA 10 µA 10 µA
Current measurement range AC 0,00001A - 10A 0,00001A - 10A 0,00001A - 10A 0,00001A - 10A 0,00001A - 10A 0,00001A - 10A
Current measuring ranges AC 10:00 AM
40 mA
400 mA
60 mA
600 mA
6:00 AM
10:00 AM
40 mA
400 mA
10:00 AM
60 mA
600 mA
6:00 AM
10:00 AM
60 mA
600 mA
10:00 AM
60 mA
600 mA
10:00 AM
Max. current measuring range, AC 10A 10A 10A 10A 10A 10A
Lowest resolution, AC current 10 µA 10 µA 10 µA 10 µA 10 µA 10 µA
Frequency range alternating current 50Hz - 1000Hz 30Hz - 1000Hz 30Hz - 1000Hz 50Hz - 2000Hz 50Hz - 2000Hz
Current sensor with clipping
Current transformer with clipping x
Resistance measurement
Milliohm measurement with 4 wire technique (Kelvin connection)
Resistance test/diode test x x x x x x
Continuity test x x x x x x
Conductivity measurement
Resistance measurement range 0.1Ohm - 40000000Ohm 0.1Ohm - 40000000Ohm 0.1Ohm - 40000000Ohm 0.1Ohm - 40000000Ohm 0.1Ohm - 66000000Ohm 0.1Ohm - 66000000Ohm
Resistance measurement ranges 40 M
400
4 k
40 k
400 k
4 M
600
6 k
60 k
600 k
6 M
40 M
400
4 k
40 k
400 k
4 M
40 M
600
6 k
60 k
600 k
6 M
40 M
600
6 k
60 k
600 k
6 M
60 m
600
6 k
60 k
600 k
6 M
60 m
Max. resistance measuring range 40MOhm 40MOhm 40MOhm 40MOhm 66MOhm 66MOhm
Lowest resolution, resistance 0.1 Ohm 0.1 Ohm 0.1 Ohm 0.1 Ohm 0.1 Ohm 0.1 Ohm
Nominal test voltage 10 V
Nominal test voltage 50 V
Nominal test voltage 100 V
Nominal test voltage 250 V
Nominal test voltage 500 V
Nominal test voltage 1000 V
Capacitance measurement
Capacitance measurement x x x x
Capacitance measuring range 0.000001µF - 200µF 0,00001µF - 400µF 0,000001µF - 40µF 0.000001µF - 40000µF
Max. capacitance measuring range 200µF 400µF 40µF 40000µF
Lowest resolution, capacitance Other 0.00001 µF Other Other
Cable length measurement
Cable symmetry testing for two wire connections a-b-E
Frequency measurement
Measuring range for frequency 0.000001kHz - 500kHz 0.0001kHz - 1000kHz 0,00001kHz - 400kHz 0.0001kHz - 1kHz 0,00001.00001kHz - 10000kHz
Max. frequency measuring range 500kHz 1000kHz 400kHz 1kHz 10000kHz
Lowest resolution, frequency 0.001 Hz 0.1 Hz 0.01 Hz 0.1 Hz 0.01 Hz
Temperature measurement
Temperature measurement x x x x x
Temperature measurement TC x x x x x
Temperature measuring range TC -50°C - 1300°C -50°C - 800°C -50°C - 400°C -50°C - 1300°C -50°C - 1300°C
Temperature measurement RTD
Max. temperature measuring range 1300°C 800°C 400°C 1300°C 1300°C
Lowest resolution, temperature 1 °C 0.1 °C 0.1 °C 1 °C 1 °C
Interface x
Bluetooth interface
IR interface x
Measured value memory
Miscellaneous
Power supply unit socket
Device protection category IP 50 IP 40 IP 50 IP 40 IP 50 IP 50
Data hold x x
Capacitance measurement ranges 4 nF
40 nF
400 nF
4µF
40µF
600 µF
60 nF
600 nF
6 µF
60 µF
6.6 mF
40 mF
Frequency measurement x x x
Current measuring range with current transformers
Clip factors

Dialogue, Information and Actions: