SECUTEST BASE SECUTEST PRO SECUTEST BASE IQ SECUTEST PRO IQ SECUTEST S2 N+ SECUTEST S2 N+10
Item number M7050-V001 M7050-V003 M705A M705C M7010-V031 M7010-V032
Product details page Details Details Details Details Details Details
HTML report x x x x
Supply voltage 90 - 250 90 - 250 90 - 250 90 - 250 115 - 230 115 - 230
Printer Connection USB-A USB-A USB-A USB-A
Indication Graphic Graphic Graphic Graphic Graphic Graphic
Automatic test sequence x x x x x x
Limit value indication x x x x x x
Measured value memory x x x x x x
Deadlines management Optional Optional Optional Optional No No
Active testing x x x x x x
Passive testing x x x x x x
Protective ground resistance measuring range 0.001Ohm - 30Ohm 0Ohm - 30Ohm 0.001Ohm - 27Ohm 0Ohm - 27Ohm 3Ohm - 30Ohm 0Ohm - 30Ohm
Isolation resistance measuring range 1MOhm - 300MOhm 0.01MOhm - 300MOhm 1MOhm - 200MOhm 0.01MOhm - 200MOhm 3MOhm - 300MOhm 0.05MOhm - 300MOhm
Protective conductor current x x x x x x
Contact current x x x x x x
Differential current method x x x x x x
Direct method x x x x x x
Alternative method x x x x x x
Consumption current measurement x x x x x x
Power measuring x x x x x x
Voltage measurement x x x x x x
Connection for external measuring adapter x x x x x x
Testing of enlarging conduits x x x x x x
Testing with 2 probes No Yes No Yes Optional Yes
Interface x x x
Printer connection x x x x
Printer integrated
Suitable for use by an instructed person x x x x x
Connection detection x x x x x x
DAkkS calibration certificate x x x x x x
Import of data Optional Yes Optional Yes No No
Integrated rubber protection x x x x
Measurement of time to trip of (P)RCDs x x x x
Save measurement series x x x x
Test current 10A x x x
remote compatible Optional Yes Optional Yes Yes Yes
Safety class detection x x x x x x
Management of location data Optional Yes Optional Yes No No
Programmable test sequences Optional Yes Optional Yes No No
Frequency of supply voltage 50 - 400 50 - 400 50 - 400 50 - 400 50 - 60 50 - 60
Description of RFID x x
Printing barcodes x x
Test sequences per VDE 0544-4 (welding equipment) x
Test sequences per IEC/EN 62353 (medical devices) x x
Data transmission to PC via BT/USB x
Test sequences for testing PRCDs x
Documentation software x
Extension for testing and managing medical devices x x
CC000739 Optional
Test sequences per IEC 60601 (medical devices)
High-voltage test 500V - 6000V
Relocation management for site data (moving test objects)

Dialogue, Information and Actions: