MAVOWATT 240 | MAVOWATT 270 | MAVOWATT 230 Mini Flex Paket | MAVOWATT 230 TR2510B Paket | MAVOWATT 270-400 Mini Flex Paket | MAVOWATT 270-400 | MAVOWATT 240 Mini Flex Paket | MAVOWATT 270 Flex Paket | MAVOWATT 240 TR2510B Paket | MAVOWATT 270 TR2510B Paket | MAVOWATT 270 Mini Flex Paket | MAVOWATT 270-400 Flex Paket | MAVOWATT 270-400 TR2510B Paket | MAVOWATT 230 Flex Paket | MAVOWATT 240 Flex Paket | MAVOWATT 230 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Item number | M820B | M820C | M820H | M820N | M820M | M820K | M820I | M820G | M820O | M820P | M820J | M820L | M820Q | M820D | M820F | M820A |
Product details page | Details | Details | Details | Details | Details | Details | Details | Details | Details | Details | Details | Details | Details | Details | Details | Details |
Indication | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic |
Current measurement | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter | With current clamp meter/clamp adapter |
Current supply | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains | Battery (rechargeable)/mains |
Communication |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Bluetooth VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Bluetooth VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Bluetooth VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Wi-Fi Bluetooth USB VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Ethernet Bluetooth VNC for full remote control of the instrument Apple and Android apps for acquisition and alarm generation GPS time synch * (see comment) |
Input | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC | Differential, voltage channels, 0 to 1000�V�AC/DC |
Measurement |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Transients as of 1µs Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Power demand and energy consumption Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Power demand and energy consumption Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Transients as of 1µs Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 400 Hz monitoring |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Transients as of 1µs Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 400 Hz monitoring |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Transients as of 1µs Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Transients as of 1µs Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Transients as of 1µs Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Transients as of 1µs Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 400 Hz monitoring |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Transients as of 1µs Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 400 Hz monitoring |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Power demand and energy consumption Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Power demand and energy consumption IEEE 1459, advanced energy Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
1000V CAT III, 600V CAT IV IEC 61000-4-30:2008, class A with certificate Sampling rate: 512 values/period/channel for U & I U-I dips and swells Transients as of 32/40µs (60/50Hz) Power demand and energy consumption Harmonics and interharmonics U (127), I (63) EN 50160, edition 3 |
Answer modules |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status | Motor status |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status |
Motor status Voltage dip direction Switching of compensation capacitors |
Motor status |
Set-ups |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Monitoring operating modes Setup wizard Max. pre/post-trigger periods |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Monitoring operating modes Setup wizard Max. pre/post-trigger periods |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Monitoring operating modes Setup wizard Max. pre/post-trigger periods |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Setup wizard Max. pre/post-trigger periods Monitoring operating modes |
Number of transient triggers Automatic setups for power quality, power demand and energy consumption Monitoring operating modes Setup wizard Max. pre/post-trigger periods |
Frequency measuring range |