• Gossen Metrawatt

Characteristic Values

METRAport 3A
Item number M113A
Product details page Details
Display
Indication Analogue
Multiple display
Measuring range selection Manual
Basic data
Type of measurement Averaging
True RMS measurement
Basic accuracy 1.5Percentage
Measuring circuit category CAT III
Max. voltage measuring circuit category 300Volt
Relative value measurement
Min. value storage
Max. value storage
Peak value memory
Data hold
Special functions
Explosion-tested version
Power and energy measurement
Harmonics analysis/power quality
Crest factor measurement
Rotational speed measuring
Duty cycle measurements
Pulse freqency measurement MHz @ 5V TTL
Inductance measurement
Interturn short-circuit high-voltage test
Automatic circuit breaker
Voltage measurement
Voltage measurement types DC
AC
With decibel measurement (dB) x
Voltage measuring range DC 0.001Volt - 600Volt
Voltage measuring ranges DC 100 mV
300 mV
1 V
3 V
10 V
30 V
100 V
300 V
600 V
Max. voltage measuring range, DC 600Volt
Lowest resolution, DC voltage 1 mV
Internal resistance volt DC 10
Voltage measuring range AC 0.001Volt - 600Volt
Voltage measuring ranges AC 100 mV
300 mV
1 V
3 V
10 V
30 V
100 V
300 V
600 V
Max. voltage measuring range, AC 600Volt
Lowest resolution, AC voltage 1 mV
Frequency range volt AC 15Hertz - 1000Hertz
Internal resistance volt AC 10
Level measurement voltage types AC
Measuring range voltage level for U ref = 0.775 V -40Decibel - 62Decibel
Lowest resolution voltage level 1Decibel
Current measurement
Current measurement types DC
AC
Current measurement range DC 0,0000001Ampere - 10Ampere
Current measuring ranges DC 10 nA
30 nA
100 nA
300 nA
1 µA
3 µA
10 µA
100 µA
1 mA
10 mA
100 mA
1:00 AM
10:00 AM
Max. current measuring range, DC 10Ampere
Lowest resolution, DC current 0.0001 µA
Current measurement range AC 0,0000001Ampere - 10Ampere
Current measuring ranges AC 10 nA
30 nA
100 nA
300 nA
1 µA
3 µA
10 µA
100 µA
1 mA
10 mA
100 mA
1:00 AM
10:00 AM
Max. current measuring range, AC 10Ampere
Lowest resolution, AC current 0.001 µA
Frequency range alternating current 15Hertz - 1000Hertz
Current sensor with clipping
Current transformer with clipping
Resistance measurement
Milliohm measurement with 4 wire technique (Kelvin connection)
Resistance test/diode test x
Continuity test x
With conductivity measurement
Resistance measurement range 1Ohm - 20000000Ohm
Resistance measurement ranges 2k
20 k
200 k
2 M
20 M
Max. resistance measuring range 20Mega-Ohm
Lowest resolution, resistance 1 Ohm
Insulation resistance measurement
Nominal test voltage 10 V
Nominal test voltage 50 V
Nominal test voltage 100 V
Nominal test voltage 250 V
Nominal test voltage 500 V
Nominal test voltage 1000 V
Capacitance measurement
Capacitance measurement
Cable length measurement
Cable symmetry testing for two wire connections a-b-E
Frequency measurement
Frequency measurement
Temperature measurement
Temperature measurement
Temperature measurement TC
Temperature measurement RTD
Interface and memory
Interface
Bluetooth interface
IR interface
Measured value memory
Miscellaneous
Power supply unit socket x

Dialogue, Information and Actions: