Characteristic Values

SECULIFE HIT AM SECULIFE HIT MD
Item number M687A M687B
Product details page Details Details
Display
Indication Analogue/digital Analogue/digital
Indication digits 12000 12000
Analogue bar graph display x x
Analogue bar graph display analogue/logarithmical
Multiple display
Measuring range selection Manual/automatic Manual/automatic
Basic data
Type of measurement TRMS TRMS
True RMS measurement x x
Basic accuracy 0.05% 0.05%
Measuring circuit category CAT IV CAT IV
Max. voltage measuring circuit category 600V 600V
Relative value measurement x x
Min. value storage x x
Maximum value storage x x
Peak value memory
Data hold x x
Special functions
Explosion-tested version
Power and energy measurement
Harmonics analysis/power quality
Crest factor measurement
Rotational speed measuring
Duty cycle measurements x x
Pulse freqency measurement MHz @ 5V TTL x x
Inductance measurement
Interturn short-circuit high-voltage test
Automatic circuit breaker
Voltage measurement
Voltage measurement types DC
AC
AC Fil
AC+DC
DC
AC
AC Fil
AC+DC
With decibel measurement (dB)
Voltage measuring range DC 0,00001V - 1000V 0,00001V - 1000V
Voltage measuring ranges DC 100 mV
1 V
10 V
100 V
1000 V
100 mV
1 V
10 V
100 V
1000 V
Max. voltage measuring range, DC 1000V 1000V
Lowest resolution, DC voltage 0.01 mV 0.01 mV
Internal resistance volt DC 10 10
Voltage measuring range AC 0,00001V - 1000V 0,00001V - 1000V
Voltage measuring ranges AC 100 mV
1 V
10 V
100 V
1000 V
100 mV
1 V
10 V
100 V
1000 V
Max. voltage measuring range, AC 1000V 1000V
Lowest resolution, AC voltage 0.01 mV 0.01 mV
Frequency range volt AC 15Hz - 20000Hz 15Hz - 20000Hz
Internal resistance volt AC 9
1
9
1
Low-pass filter AC voltage (fc) 1kHz 1kHz
Voltage measuring range AC+DC 0,00001V - 1000V 0,00001V - 1000V
Voltage measuring ranges AC+DC 100 mV
1 V
10 V
100 V
1000 V
100 mV
1 V
10 V
100 V
1000 V
Max. voltage measuring range, AC+DC 1000V 1000V
Lowest resolution volt AC+DC 0.01mV 0.01mV
Internal resistance volt AC+DC 9 9
Frequency range volt AC+DC 20kHz 20kHz
Current measurement
Current measurement types DC
AC
AC+DC
DC
AC
AC+DC
Current measurement range DC 0,00000001A - 10A 0,00000001A - 10A
Current measuring ranges DC 0.1 mA
1 mA
10 mA
100 mA
1:00 AM
10:00 AM
0.1 mA
1 mA
10 mA
100 mA
1:00 AM
10:00 AM
Max. current measuring range, DC 10A 10A
Lowest resolution, DC current 0.01 µA 0.01 µA
Current measurement range AC 0,00000001A - 10A 0,00000001A - 10A
Current measuring ranges AC 0.1 mA
1 mA
10 mA
100 mA
1:00 AM
10:00 AM
0.1 mA
1 mA
10 mA
100 mA
1:00 AM
10:00 AM
Max. current measuring range, AC 10A 10A
Lowest resolution, AC current 0.01 µA 0.01 µA
Frequency range alternating current 15Hz - 10000Hz 15Hz - 10000Hz
Current measurement range AC+DC 0,00000001A - 10A 0,00000001A - 10A
Current measuring ranges AC+DC 0.1 mA
1 mA
10 mA
100 mA
1:00 AM
10:00 AM
0.1 mA
1 mA
10 mA
100 mA
1:00 AM
10:00 AM
Max. current measuring range AC + DC 10A 10A
Lowest resolution amps AC+DC 0,00001mA 0,00001mA
Frequency range amps AC+DC 10kHz 10kHz
Current sensor with clipping x x
Current measuring range with current sensors 0.00001A - 10000A 0.00001A - 10000A
Current transformer with clipping x x
Current measuring range with current transformers 0.00001A - 10000A 0.00001A - 10000A
Clip factors 01:01
01:10
0,111111111
0,736111111
01:01
01:10
0,111111111
0,736111111
Resistance measurement
Milliohm measurement with 4 wire technique (Kelvin connection)
Continuity test x x
Conductivity measurement
Resistance measurement range 0.01Ohm - 40000000Ohm 0.01Ohm - 40000000Ohm
Resistance measurement ranges 100
1 k
10 k
100 k
1 M
10 M
40 M
100
1 k
10 k
100 k
1 M
10 M
40 M
Max. resistance measuring range 40MOhm 40MOhm
Lowest resolution, resistance 0.01 Ohm 0.01 Ohm
Lowest resolution, milliohm measurement 10mOhm 10mOhm
Nominal test voltage 10 V
Nominal test voltage 50 V
Nominal test voltage 100 V
Nominal test voltage 250 V
Nominal test voltage 500 V
Nominal test voltage 1000 V
Capacitance measurement
Capacitance measurement x x
Capacitance measuring range 0,00001µF - 1000µF 0,00001µF - 1000µF
Capacitance measurement ranges 10 nF
100 nF
1 µF
10µF
100µF
1000 µF
10 nF
100 nF
1 µF
10µF
100µF
1000 µF
Max. capacitance measuring range 1000µF 1000µF
Lowest resolution, capacitance 0.00001 µF 0.00001 µF
Cable length measurement
Cable symmetry testing for two wire connections a-b-E
Frequency measurement
Frequency measurement x x
Measuring range for frequency 0,00001kHz - 1000kHz 0,00001kHz - 1000kHz
Max. frequency measuring range 1000kHz 1000kHz
Lowest resolution, frequency 0.01 Hz 0.01 Hz
Temperature measurement
Temperature measurement x x
Temperature measurement TC x x
Temperature measuring range TC -250°C - 1372°C -250°C - 1372°C
Temperature measurement RTD x x
Temperature measuring range RTD -200°C - 850°C -200°C - 850°C
Max. temperature measuring range 1372°C 1372°C
Lowest resolution, temperature 0.1 °C 0.1 °C
Interface and memory
Interface x x
Bluetooth interface
IR interface x x
Measured value memory x x
Memory capacity for measured values 15400 15400
Miscellaneous
Power supply unit socket x x
Device protection category IP 65 IP 65

Dialogue, Information and Actions: